CBPDY - AROCLOR 1260 SOLUTION IN ISOOCTANE, EPC00709

  • MSDS: CBPDY
  • Manufacturer: EM SCIENCE
  • Product Name: AROCLOR 1260 SOLUTION IN ISOOCTANE, EPC00709
  • National Stock Number: 6810-00N071615
Product Identification

Product ID:AROCLOR 1260 SOLUTION IN ISOOCTANE, EPC00709
MSDS Date:12/09/1993
FSC:6810
NIIN:00N071615
MSDS Number: CBPDY

Responsible Party
EM SCIENCE
480 DEMOCRAT RD
GIBBSTOWN, NJ 08027
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 609-354-9200

Cage: DO242

Contractor
EM SCIENCE
70 GIBBSTOWN, NJ 08927 US

Telephone: 800-424-9300 (CHEMTREC)

Cage: DO242

Ingredients

POLYCHLORINATED BIPHENYL (AROCLOR 1260); (AROCLOR 1260)

CAS: 11096-82-5

RTECS: TQ1362000

Fraction By Weight: 0.0035%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


PENTANE, 2,2,4-TRIMETHYL-; (ISOOCTANE) (CERCLA)

CAS: 540-81-1

RTECS: SA3320000

Fraction By Weight: 99.99%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:VAPOR IRRITATING TO EYES AND
RESPIRATORY PASSAGES. INHALATION MAY CAUSE DIZZINESS, NAUSEA, LACK
OF COORDINATION, NARCOSIS, UNCONSCIOUSNESS. INGESTION MAY CAUSE
DIARRHEA, SLIGHT CENTRAL NERVOUS SYSTEM DEPRESSION, DIFFICULTY
BREATHING & FATIGUE. ISOOCTANE HAS PRODUCED KIDNEY DAMAGE IN RATS
IN A (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:SUBCHRONIC ORAL LABORATORY STUDY.
CONTACT WITH SKIN AND EYES MAY CAUSE MILD IRRITATION. CONTAINS
COMPONENT(S) WHICH ARE POSSIBLE CANCER HAZARD(S) IN QUANTITIES LESS
THAN 0.1%.
Medical Cond Aggravated by Exposure:NONE INDICATED.

First Aid

First Aid:GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE.
SKIN:WASH THOROUGHLY W/SOAP & WATER. EYES:IMMEDIATELY FLUSH
THOROUGHLY W/WATER FOR AT LEAST 15 MINUTES. INHAL:REMOVE TO FRESH
AIR; GIVE ARTIFICIAL RESPIRATION IF BREATHING HAS STOPPED.
INGEST:DO NOT INDUCE VOMITING; GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:CC
Flash Point:10F,-12C
Lower Limits:1%
Upper Limits:6%
Extinguishing Media:DRY CHEMICAL, CO*2, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:DANGEROUS FIRE HAZARD. VAPOR CAN TRAVEL
DISTANCES TO IGNITION SOURCE & FLASH BACK.

Accidental Release

Spill Release Procedures:EVACUATE AREA OF ALL UNNEC PERS. WEAR SUITABLE
PROT EQUIP LISTED UNDER EXPOS/PERSONAL PROT. ELIM ANY IGNIT SOURCES
UNTIL AREA IS DETERMINED TO BE FREE FROM EXPLO/FIRE HAZS. CONTAIN
RELS & ELIM ITS SOU RCE, IF THIS CAN BE DONE W/OUT RISK. TAKE
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
IN A COOL AREA AWAY FROM IGNITION SOURCES & OXIDIZERS. DO NOT
BREATHE VAPOR. DO NOT TAKE INTERNALLY.
Other Precautions:DO NOT GET IN EYES, ON SKIN OR ON CLOTHING.
ELECTRICALLY GROUND ALL EQUIPMENT WHEN HANDLING THIS PRODUCT. FOR
RESEARCH & DEVELOPMENT USE ONLY. NOT FOR MANUFACTURING OR
COMMERCIAL PURPOSES.

Exposure Controls

Respiratory Protection:IF WORKPLACE EXPOS LIM(S) OF PROD/ANY COMPONENT
IS EXCEEDED, A NIOSH/MSHA APPRVD AIR SUPPLIED RESP IS ADVISED IN
ABSENCE OF PROPER ENVIRON CONTROL. OSHA REGS ALSO PERMIT OTHER
NIOSH/MSHA APPRVD RESPS (NEG PRESS TYPE) UNDER SPECIFIED(SUPDAT)
Ventilation:MATERIAL MUST BE HANDLED OR TRANSFERRED IN AN APPROVED FUME
HOOD OR W/EQUIVALENT VENTILATION.
Protective Gloves:NITRILE OR EQUIVALENT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . SAFETY EQUIPMENT SHOULD BE READILY
AVAILABLE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
SPILL PROC:UP & CONTAINERIZE FOR PROPER DISPOSAL. COMPLY W/FEDERAL,
STATE & LOCAL REGULATIONS. RESP PROT:CONDITIONS (SEE YOUR SAFETY
EQUIPMENT SUPPLIER). ENGINEERING &/OR ADMINISTRATIVE CONTROLS SHOUL
D BE IMPLEMENTED TO REDUCE EXPOSURE.

Chemical Properties

Boiling Pt:B.P. Text:210F,99C
Melt/Freeze Pt:M.P/F.P Text:-161F,-107C
Vapor Pres:41 @ 21C
Vapor Density:3.9
Spec Gravity:0.69 (H*2O=1)
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR LIQUID; MILD ODOR.
Percent Volatiles by Volume:>99

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:HEAT; CONTACT W/IGNITION SOURCES.
Hazardous Decomposition Products:CO*X.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.